Product Configurator - 38R Self-Acting Temperature Control Valve

Enter Your Model Number
product main image
Model Number

38R-X-X

38R Self-Acting Temperature Control Valve

Model Number & Pricing Incomplete
Lead Time: 58 Days
List Price: $0.00
Net Options: $0.00

Step 1: Select Required Options

    Action

  • 0 Replacement Actuator Only
  • 3 3-Way
  • D 2-Way Direct Acting
  • R 2-Way Reverse Acting

    Connection & Port Size

  • A1 1/2" Connection with 1/8" Port
  • A2 1/2" Connection with 3/16" Port
  • A3 1/2" Connection with 1/4" Port
  • A4 1/2" Connection with 3/8" Port
  • B1 3/4" Connection with 1/8" Port
  • B2 3/4" Connection with 3/16" Port
  • B3 3/4" Connection with 1/4" Port
  • B4 3/4" Connection with 3/8" Port
  • B5 3/4" Connection with 1/2" Port
  • C1 1" Connection with 1/8" Port
  • C2 1" Connection with 3/16" Port
  • C3 1" Connection with 1/4" Port
  • C4 1" Connection with 3/8" Port
  • C5 1" Connection with 1/2" Port
  • C6 1" Connection with 3/4" Port
  • 00 1/2" Full Port
  • 01 3/4" Full Port
  • 02 1" Full Port
  • 03 1-1/4" Full Port
  • 04 1-1/2" Full Port
  • 05 2" Full Port
  • 06 2-1/2" Full Port
  • 07 3" Full Port
  • 08 4" Full Port
  • 09 5" Full Port
  • 10 6" Full Port

    Valve Seat

  • 0 Replacement Actuator Only
  • V Single Seat
  • W Double Seat

    Valve Plug Type (Internal)

  • 0 Replacement Actuator Only
  • A Linear

    Body Material

  • 0 Replacement Actuator Only
  • 1 Cast Iron
  • 2 Cast Steel
  • 3 Bronze
  • 4 316 SS

    Trim Material (Internal)

  • 0 Replacement Actuator Only
  • 1 Bronze
  • 2 316 SS

    Actuator

  • 0 Replacement Body Only
  • 1 Non-Indicating
  • 2 Indicating
  • 3 Fail-Safe

    Bulb & Capillary

  • 00 Replacement Body Only
  • 01 Brass Union Hub, Copper Bulb & Capillary
  • 02 SST Union Hub, SST Bulb & Capillary
  • 03 Brass Adjustable Union Hub, Copper Bulb & Capillary
  • 04 SST Adjustable Union Hub, SST Bulb & Capillary
  • 05 Copper Bulb & Capillary Only
  • 06 SST Bulb & Capillary Only
  • 07 Copper with FEP Covering Bulb & Capillary Only
  • 08 SST with FEP Covering Bulb & Capillary Only
  • 09 Brass Union Hub, Copper Bulb & Capillary, SST Armor
  • 10 SST Union Hub, SST Bulb & Capillary, SST Armor

    Capillary Length

  • 00 Replacement |Body Only
  • 08 8 Feet
  • 12 12 Feet
  • 16 16 Feet
  • 20 20 Feet
  • 24 24 Feet
  • 28 28 Feet
  • 32 32 Feet
  • 36 36 Feet
  • 40 40 Feet
  • 44 44 Feet
  • 48 48 Feet
  • 52 52 Feet

    Well

  • 0 None
  • 1 316 SS
  • 2 Brass

    Range

  • 000 Replacement Actuator Only
  • R01 20 to 70°F (-10 to 20°C)
  • R02 40 to 90°F (5 to 30°C)
  • R03 30 to 115°F (0 to 45°C)
  • R04 50 to 140°F (10 to 60°C)
  • R05 75 to 165°F (25 to 70°C)
  • R06 105 to 195°F (40 to 90°C)
  • R07 125 to 215°F (55 to 100°C)
  • R09 155 to 250°F (70 to 120°C)
  • R10 200 to 280°F (95 to 135°C)
  • R11 225 to 315°F (110 to 155°C)
  • R12 255 to 370°F (125 to 185°C)
  • R13 295 to 420°F (145 to 215°C)
  • R14 310 to 440°F (155 to 225°C)
  • R81 40 to 65°F (5 to 20°C)
  • R82 55 to 80°F (15 to 25°C)
  • R83 65 to 90°F (20 to 30°C)
  • R84 81 to 110°F (25 to 40°C)
  • R85 90 to 115°F (30 to 45°C)
  • R86 110 to 140°F (40 to 60°C)
  • R89 140 to 175°F (60 to 80°C)
  • R90 170 to 195°F (80 to 90°C)
  • R91 190 to 210°F (85 to 100°C)
  • R92 205 to 225°F (95 to 105°C)
  • R93 215 to 250°F (100 to 120°C)
  • R94 230 to 265°F (110 to 130°C)
  • R95 245 to 280°F (120 to 135°C)
  • R96 270 to 300°F (135 to 150°C)