Series CDTR Carbon Dioxide/RH/Temperature Transmitter
NDIR CO2 Sensor, Universal CO2/RH Outputs, Optional Relay
The Series CDTR Carbon Dioxide, Relative Humidity and Temperature
Transmitters reduce the number of sensors mounted on a wall or in a duct. By
combining CO 2 , RH, and temperature in one device, system integrators are able to
reduce installation time while lowering material cost at the same time.
Like our popular Series CDT Carbon Dioxide Transmitter, a non-dispersive infrared
(NDIR) sensor is used to make the CO 2 measurement. In order to achieve the
best possible accuracy, the Series CDTR also includes digital barometric pressure
adjustment.
Universal outputs for both carbon dioxide and relative humidity allow users to select
the transmitter output to be 4-20 mA, 0-5 VDC, or 0-10 VDC to work with virtually any
building management controller. Additionally, passive thermistor or RTD sensor can be
ordered for a temperature output.
For applications that require visual indication, the wall mount configurations of the
Series CDTR can be ordered with an integral LCD display. The display can be
configured to display temperature only, relative humidity only, CO2 only, CO 2 and
humidity, or CO2 and temperature. To prevent tampering, the action of the buttons can
be locked out using an internal jumper selection.
Product Applications
- Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
- LEED® certification
Models & Ordering
Specifications
- Range:
- CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Relative humidity: 0 to 100% ; Temperature: 32 to 122°F (0 to 50°C).
- Accuracy:
- ±40 ppm + 3% of reading (CO2); ±2% (RH).
- Temperature Dependence:
- ±8 ppm/ °C at 1100 ppm.
- Non-Linearity:
- 16 ppm.
- Pressure Dependence:
- 0.13% of reading per mm of Hg.
- Response Time:
- 2 minutes for 99% step change.
- Temperature Limits:
- 32 to 122°F (0 to 50°C).
- Duct Air Velocity Range:
- 0-4000 FPM (20.32 m/s).
- Humidity Limits:
- 10 to 95% RH (non-condensing).
- Power Requirements:
- 16 to 35 VDC / 19 to 28 VAC.
- Power Consumption:
- Average: 2 watts; Peak: 3.75 watts.
- Sensor:
- Single-beam, dual-wavelength NDIR.
- Output:
- Current: 4 to 20 mA (max 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω); Relay: SPST NO 2A @ 30 VDC; RTD or thermistor per r-t curves (depending on model).
- Enclosure Rating:
- Duct mount: NEMA 4X (IP66) for housing only; Wall mount: IP20.
- Compliance:
- CE.
Features
- Digital Intelligence Temperature Compensation Algorithm (DITCA™) eliminates error due to the self heating effects of wall mount combination devices
- Single beam dual wavelength NDIR CO2 sensor
- Replaceable humidity/temperature sensors
- Physical hardware lockout
- Service display tool available for duct mount and wall mount units without an LCD
- Relay output option
Accessories
Model Number | Description | Usually Ships* | Price | Order | |
---|---|---|---|---|---|
![]() |
A-449 | Remote display with mini USB display. | Next Day | $65.00 | Order |
![]() |
A-CDT-KIT | Accessory kit including terminal block and power supply. | 1-2 Weeks | $51.00 | Order |
![]() |
A-449A | Remote display with push buttons and mini USB. (Necessary for models with –NBC option) | Less Than 1 Week | $130.00 | Order |
Videos
Model Chart
EXAMPLE | CDTR | 2 | W | 4 | 0 | 4 | LCD | Series CDTR-2W404-LCD, Carbon Dioxide/RH/Temperature Transmitter, gas concentration range 2000 ppm, wall mount, carbon dioxide output 0-5 VDC/0-10VDC/4-20mA, RH output 0-5 VDC/0-10 VDC/4-20 mA, LCD display |
SERIES | CDTR | Carbon Dioxide/RH/Temperature Transmitter | ||||||
GAS CONCENTRATION RANGE | 2 5 |
2000 ppm 5000 ppm |
||||||
MOUNTING CONFIGURATION | D N |
Duct Mount North American Wall Mount |
||||||
CARBON DIOXIDE OUTPUT | 4 | 0-5 VDC/0-10 VDC/4-20mA | ||||||
TEMPERATURE OUTPUT | 0 A B C D E F |
NONE 10K OHM Type 3 NTC Thermistor 10K OHM Type 2 NTC Thermistor 3K OHM NTC Thermistor (not available with Mtg Option E, N) PT100 OHM RTD PT1000 OHM RTD 20K OHM NTC Thermistor |
||||||
RH OUTPUT | 4 | 0-5 VDC/0-10 VDC/4-20 mA | ||||||
OPTIONS | FC LCD RLY |
Factory Calibration Certificate LCD Display Relay Output |
Product Literature
Manuals
- AQ-CDTR Duct Mount Manual (Pre April 2022)
- AQ-CDTR Duct Mount Manual (Post April 2022)
- AQ-CDTR-N Wall Mount Manual (Pre April 2022)
- AQ-CDTR-N Wall Mount Manual (Post April 2022)
Catalog Pages
Product Data Sheet
Approvals
Photo Downloads
You must be logged in to view this content.Click here to login to your account.